NSN 5925-00-871-6497 · NIIN 008716497 · FSC 5925
NO DASHES 5925008716497
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
34 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CQJX | NOMINAL THREAD SIZE | INCHES 0.138 |
| AJEC | BOSS HEIGHT | INCHES NOMINAL 0.130 |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION MAGNETIC-HYDRAULIC |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| MATT | MATERIAL | CASE PLASTIC |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 2.200 AND MAXIMUM AT 200 PCT 20.000 |
| AAQL | BODY STYLE | |
| ADAQ | BODY LENGTH | INCHES NOMINAL 2.000 |
| ADAT | BODY WIDTH | INCHES NOMINAL 0.750 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 1.660 |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES NOMINAL 1.890 |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 10.0 |
| FREQ | FREQUENCY IN HERTZ | 50.0 OR 60.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 250.0 |
| AKPX | POLE QUANTITY | 1 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 2 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | QUICK DISCONNECT, MALE 2 |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 5000.0 |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 1.530 |
| CTJS | UNPACKAGED UNIT WEIGHT | OUNCES NOMINAL 2.200 |
| CPRQ | RESET METHOD | MANUAL |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
Cross-references
7 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 790-265 | 53468 |
| JA1S-D3-10-2 | 74193 |
| W67-X2Q12-10 | 77342 |
| 537-210-101 | 77342 |
| UPG1-1-62-103-90 | 82415 |
| UPG1-1-62-103-90 | 81541 |
| 62828-90037-7 | 97384 |