| MRC | Requirement | Value |
|---|---|---|
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SECOND LOCATION DC 28.0 |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | EXPLOSION RESISTANT AND MOISTURE RESISTANT |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | SINGLE LOCATION CELSIUS NOMINAL 25.0 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION THERMAL |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-5809 |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 10.000 AND MAXIMUM AT 200 PCT 70.000 |
| THSD | THREAD SERIES DESIGNATOR | UNS |
| TTQY | TERMINAL TYPE AND QUANTITY | SCREW 2 |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES NOMINAL 1.312 |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 25.0 AND AMPERES DC 25.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | FIRST LOCATION AC 115.0 |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.469 |
| AAQL | BODY STYLE | |
| ABXD | BUSHING LENGTH | INCHES NOMINAL 0.344 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 1.375 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 0.750 |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 0.906 |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | PUSH-PULL 1 |
| AKPX | POLE QUANTITY | 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED BUSHING 1 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | FIRST LOCATION AC 3500.0 |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SECOND LOCATION DC 6000.0 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 7271-8-25 | 82647 |
| D7271-8-25 | 82647 |
| MS24510A25 | 96906 |