CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
33 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | FIRST LOCATION AMPERES DC 4.0 |
| CPRL | TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS TIME DELAY |
| CPRJ | TRIP RELEASE METHOD | ALL LOCATIONS MAGNETIC |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SECOND LOCATION AMPERES DC 4.0 |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SECOND LOCATION RELAY TRIP |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | THIRD LOCATION SERIES TRIP |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.375 |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | ALL LOCATIONS NOMINAL AT 150 PCT 0.280 |
| THSD | THREAD SERIES DESIGNATOR | UNEF |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE HOOK 10 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED BUSHING WITH PANEL SEAL 1 |
| CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | ALL LOCATIONS NOMINAL 0.500 |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | FIRST LOCATION RELAY TRIP |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | THIRD LOCATION AC 240.0 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | THIRD LOCATION AMPERES AC 6.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | FIRST LOCATION DC 50.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SECOND LOCATION DC 50.0 |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| AAQL | BODY STYLE | |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | INCHES NOMINAL 0.625 |
| AKPX | POLE QUANTITY | 3 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 1.937 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS DC 500.0 |
| CPRH | CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERCURRENT |
| ABXD | BUSHING LENGTH | INCHES NOMINAL 0.330 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 1.562 |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 0.875 |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 260-0953-010 | 74193 |
| 79-149-1 | 74193 |
| 3724 | 02227 |