Home / MS parts / NSN 5925-00-925-2164
NSN 5925-00-925-2164  ·  NIIN 009252164  ·  FSC 5925
NO DASHES 5925009252164
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

39 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AKPXPOLE QUANTITY3
ABXDBUSHING LENGTHINCHES MAXIMUM 0.375
AAJETHREAD PITCH DIAMETERSINCHES 0.3503 TO 0.3537
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
ADAQBODY LENGTHINCHES MAXIMUM 1.500
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLETHIRD LOCATION AMPERES AC 2.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0
AAQLBODY STYLE
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.625
AFJNFRAGILITY FACTORMODERATELY RUGGED
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT130.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.780
FREQFREQUENCY IN HERTZ400.0
PMLCPRECIOUS MATERIAL AND LOCATIONSILVER CONTACT SURFACES
PRMTPRECIOUS MATERIALSILVER
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.375
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 1.000 AND MAXIMUM AT 200 PCT 5.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT AND HERMETICALLY SEALED
CTJSUNPACKAGED UNIT WEIGHTOUNCES NOMINAL 4.500
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
ADATBODY WIDTHINCHES MAXIMUM 1.875
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEFIRST LOCATION AMPERES AC 1.6
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESECOND LOCATION MILLIAMPERES AC 0.25
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.875
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 300.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
TTQYTERMINAL TYPE AND QUANTITYWIRE HOOK 6
THSDTHREAD SERIES DESIGNATORUNEF

Cross-references

4 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
G330011S1724930
G330011S1774193
SM333-L1.6-C0.25-R2.0-240V400C174193
AP111-165-1781541