NSN 5925-00-993-0367 · NIIN 009930367 · FSC 5925
NO DASHES 5925009930367
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
22 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 3500.0 AND DC 6000.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 120.0 AND DC 30.0 |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 200.0 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 0.560 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 2.190 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED BUSHING 1 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 10.0 AND AMPERES DC 10.0 |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | SINGLE LOCATION CELSIUS NOMINAL 25.0 |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| MATT | MATERIAL | CASE PLASTIC |
| TTQY | TERMINAL TYPE AND QUANTITY | SCREW 2 |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | PUSH-PULL 1 |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 0.200 AND MAXIMUM AT 200 PCT 0.700 |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND EXPLOSION PROOF |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION INSTANTANEOUS AND TIME DELAY |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| AKPX | POLE QUANTITY | 1 |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION THERMAL |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 0.750 |
| CPRQ | RESET METHOD | MANUAL |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 7274-2-10 | 82647 |