NSN 5925-01-031-4861 · NIIN 010314861 · FSC 5925
NO DASHES 5925010314861
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
35 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAQL | BODY STYLE | |
| ABXD | BUSHING LENGTH | INCHES MINIMUM 0.332 AND INCHES MAXIMUM 0.380 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 1.562 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 0.625 |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MAXIMUM 0.906 |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES MAXIMUM 1.700 |
| AKPX | POLE QUANTITY | 1 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED BUSHING WITH PANEL SEAL 1 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 2.0 AND AMPERES DC 2.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 240.0 AND DC 50.0 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 300.0 AND DC 500.0 |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION MAGNETIC |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.375 |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 0.055 AND MAXIMUM AT 200 PCT 0.950 |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND VIBRATION RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT |
| CTJS | UNPACKAGED UNIT WEIGHT | GRAMS NOMINAL 50.0 |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39019 |
| THSD | THREAD SERIES DESIGNATOR | UNEF |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE HOOK 2 |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT SPECIFICATION 81349--IL-C-39019 TO 1 |
Cross-references
29 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| ES1843-4A202 | 20418 |
| AP1-1-71-202 | 4K035 |
| SM3-2.00 | 74193 |
| SM3-2-230VAC400C2 | 74193 |
| SM3-2-230-400-58 | 74193 |
| SM3-2-60-2 | 74193 |
| SM3-2-230-60-58 | 74193 |
| SM3-2-115-60HZ2 | 74193 |
| HB1Z1-83 | 74193 |
| 77-102-1 | 74193 |
| M39019/1-81 | 81349 |
| M39019-1-85 | 81349 |
| M39019-1-83 | 81349 |
| MIL-C-39019/1 | 81349 |
| M39019/01-218 | 81349 |
| MIL-PRF-39019/1 | 81349 |
| AP1-1-61-202 | 81541 |
| AP-1-1-7-1-202 | 82227 |
| AP1-2-1-115VAC400 | 81541 |
| KS10404-4 | 84955 |
| 7618289P164 | 99971 |
| 5925004351716 | A00AM |
| 457-6139 | A486G |
| X24-303-447 | S3715 |
| 10341447 | S3715 |
| 3A/C31913/1 | U4338 |
| 260-4051-330 | 13499 |
| 9177431 | 18876 |
| 10611501-1 | 18876 |
Supersedes
This item replaces cancelled NIINs 001111737 · 001111736 · 004351716 · 004900273 · 008435269 · 008440453 · 008999551 · 008912421 · 009288256 · 009524546 · 009586241 · 010153851 · 009912092 · 009912091. An older drawing citing one of those numbers resolves here.