Home / MS parts / NSN 5925-01-035-6578
NSN 5925-01-035-6578  ·  NIIN 010356578  ·  FSC 5925
NO DASHES 5925010356578
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

38 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES MINIMUM 0.332 AND INCHES MAXIMUM 0.380
ADAQBODY LENGTHINCHES MINIMUM 1.531 AND INCHES MAXIMUM 1.562
ADATBODY WIDTHINCHES MINIMUM 0.594 AND INCHES MAXIMUM 0.625
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 0.875 AND INCHES MAXIMUM 0.906
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 1.669 AND INCHES MAXIMUM 1.700
AKPXPOLE QUANTITY1
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION MILLIAMPERES AC 50.0 AND MILLIAMPERES DC 50.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 240.0 AND DC 50.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 300.0 AND DC 500.0
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
CPRJTRIP RELEASE METHODSINGLE LOCATION MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
CPRPULTIMATE TRIP TIME PER POLE IN SECONDSSINGLE LOCATION MINIMUM 0.200 AND MAXIMUM 7.000
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP W/AUXILIARY LOAD TERMINAL
CQJXNOMINAL THREAD SIZEINCHES 0.375
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 0.500 AND MAXIMUM AT 200 PCT 9.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
CRTKSWITCH TERMINAL TYPEPIN
CSSXSWITCH CURRENT RATING AND TYPE IN AMPSAC 0.5 AND DC 0.5
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 120.0 AND DC 50.0
CTJSUNPACKAGED UNIT WEIGHTGRAMS NOMINAL 50.0
FREQFREQUENCY IN HERTZ400.0
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-RF-39019
THSDTHREAD SERIES DESIGNATORUNEF
TTQYTERMINAL TYPE AND QUANTITYWIRE HOOK 2
ZZZKSPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-RF-39019 TO 2

Cross-references

4 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
MIL-C-39019/281349
M39019/2-1081349
M39019/02-20181349
MIL-PRF-39019/281349