NSN 5925-01-158-0762 · NIIN 011580762 · FSC 5925
NO DASHES 5925011580762
In Stock
CIRCUIT BREAKER
Circuit Breakers
Application: VEHICLE APPLICATION; ONE TON AMMUNITION CARRIER; CARGO TRUCK
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.174 |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AGAV | END ITEM IDENTIFICATION | VEHICLE APPLICATION; ONE TON AMMUNITION CARRIER; CARGO TRUCK |
| AKPX | POLE QUANTITY | 8 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 16 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | EIGHTH LOCATION AMPERES DC 20.0 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | THIRD LOCATION AMPERES DC 15.0 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SEVENTH LOCATION AMPERES DC 15.0 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | FOURTH LOCATION AMPERES DC 15.0 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | FIFTH LOCATION AMPERES DC 15.0 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | FIRST LOCATION AMPERES DC 15.0 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SIXTH LOCATION AMPERES DC 15.0 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SECOND LOCATION AMPERES DC 15.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS DC 28.0 |
| CPRJ | TRIP RELEASE METHOD | ALL LOCATIONS MAGNETIC |
| CPRQ | RESET METHOD | AUTOMATIC |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | ALL LOCATIONS SERIES TRIP |
| TTQY | TERMINAL TYPE AND QUANTITY | THREADED STUD 16 |