NSN 5925-01-165-2913 · NIIN 011652913 · FSC 5925
NO DASHES 5925011652913
In Stock
CIRCUIT BREAKER
Circuit Breakers
Application: 2320-01-121-2102
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAQL | BODY STYLE | |
| ABHP | OVERALL LENGTH | INCHES MINIMUM 1.235 AND INCHES MAXIMUM 1.265 |
| ABKW | OVERALL HEIGHT | INCHES MINIMUM 0.425 AND INCHES MAXIMUM 0.455 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 0.500 |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AGAV | END ITEM IDENTIFICATION | 2320-01-121-2102 |
| AKPX | POLE QUANTITY | 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | CLIP 2 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 6.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 12.0 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 1000.0 |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION THERMAL-MAGNETIC |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION INSTANTANEOUS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| CPRQ | RESET METHOD | AUTOMATIC |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | SINGLE LOCATION CELSIUS NOMINAL 25.0 |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| MATT | MATERIAL | CASE PLASTIC |
| TTQY | TERMINAL TYPE AND QUANTITY | THREADED STUD 2 |