NSN 5925-01-574-2829 · NIIN 015742829 · FSC 5925
NO DASHES 5925015742829
In Stock
CIRCUIT BREAKER
Circuit Breakers
Application: BOAT, RIGID INFLATABLE, 7 METER, 7MMM0701, 0702, 0703 AND 7MRX0701
Technical characteristics
6 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AGAV | END ITEM IDENTIFICATION | BOAT, RIGID INFLATABLE, 7 METER, 7MMM0701, 0702, 0703 AND 7MRX0701 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES DC 3000.0 |
| FEAT | SPECIAL FEATURES | OPERATING TEMP -25 DEG C TO +82 DEG C; THERAMLLY RESPONSIV BI-METAL BLADE; TYPE III SWITCHABLE/ MANUAL RESET- TRIP FREE; STUD SIZE 1/4IN-28 |
| SUPP | SUPPLEMENTARY FEATURES | MATERIAL IS PHENOLIC; MOUNTING HOLES ACCEPT 1/4IN (M6) SCREW |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION DC 42.0 |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | CIRCUIT BREAKER |