NSN 5925-01-590-7079 · NIIN 015907079 · FSC 5925
NO DASHES 5925015907079
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 10.0 AND AMPERES DC 10.0 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 2 |
| AKPX | POLE QUANTITY | 1 |
| ADAU | BODY HEIGHT | MILLIMETERS NOMINAL 61.0 |
| ADAQ | BODY LENGTH | MILLIMETERS NOMINAL 58.7 |
| ADAT | BODY WIDTH | MILLIMETERS NOMINAL 19.1 |
| AAQL | BODY STYLE | |
| MATT | MATERIAL | CASE PLASTIC |
| TTQY | TERMINAL TYPE AND QUANTITY | SCREW 2 |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | ROCKER ACTUATOR 1 |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION MAGNETIC-HYDRAULIC |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 120.0 AND AC 250.0 AND DC 32.0 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 1500.0 AND DC 5000.0 |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| CPRQ | RESET METHOD | MANUAL |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 7402 | 1Q449 |