Home / MS parts / NSN 5925-01-729-2398
NSN 5925-01-729-2398  ·  NIIN 017292398  ·  FSC 5925
NO DASHES 5925017292398
In Stock

CIRCUIT BREAKER

Circuit Breakers

Application: 5895-01-706-1415

Technical characteristics

32 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CPRWACTUATOR FUNCTIONTRIP-RESET
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
CBBLFEATURES PROVIDEDHIGH INRUSH PROTECTION
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES DC 12.5
THSDTHREAD SERIES DESIGNATORUNEF AND UNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYSCREW 4
CQJXNOMINAL THREAD SIZEINCHES 0.375 AND INCHES 0.138
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CRCFTRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 25.0
CTTCTHREAD TOLERANCE CLASSINTERNAL 2B AND EXTERNAL 2A
CXCYPART NAME ASSIGNED BY CONTROLLING AGENCYCIRCUIT BREAKERS, MAGNETIC, LOW-POWER, SEALED, TRIP-FREE TWO-POLE
FEATSPECIAL FEATURESFREQUESNCY: MAXIMUM AT 60 HZ AND 400 HZ;
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRQRESET METHODMANUAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 0.750
AGAVEND ITEM IDENTIFICATION5895-01-706-1415
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.950
AKPXPOLE QUANTITY2
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MAXIMUM 0.906
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.625
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349,-IL-RF-39019
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES MINIMUM 0.332 AND INCHES MAXIMUM 0.380
ADAQBODY LENGTHINCHES MAXIMUM 1.562
ADATBODY WIDTHINCHES MAXIMUM 1.281
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0 AND DC 50.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 300.0 AND DC 500.0
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1

Cross-references

3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
MIL-PRF-M39019/381349
MIL-PRF-39019/381349
M39019/03-251S81349