Home / MS parts / NSN 5925-00-946-6879
NSN 5925-00-946-6879  ·  NIIN 009466879  ·  FSC 5925
NO DASHES 5925009466879
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

30 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ADATBODY WIDTHINCHES MAXIMUM 0.580
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 100.0 AND DC 100.0
CPRJTRIP RELEASE METHODSINGLE LOCATION THERMAL
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT145.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
CPRWACTUATOR FUNCTIONTRIP-RESET
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.593
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.438
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 20.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDEXPLOSION RESISTANT AND MOISTURE RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
FREQFREQUENCY IN HERTZ400.0
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-5809
THSDTHREAD SERIES DESIGNATORUN
TTQYTERMINAL TYPE AND QUANTITYSCREW 2
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.420
AKPXPOLE QUANTITY1
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION MILLIAMPERES AC 500.0 AND MILLIAMPERES DC 500.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 115.0 AND DC 28.0
CMLPTHREAD QUANTITY PER INCH32
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
AAQLBODY STYLE
ADAQBODY LENGTHINCHES MAXIMUM 0.780
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
ABXDBUSHING LENGTHINCHES NOMINAL 0.359

Supersedes

This item replaces cancelled NIINs 006055885 · 009059180 · 009784485. An older drawing citing one of those numbers resolves here.