Home / MS parts / NSN 5925-01-187-0695
NSN 5925-01-187-0695  ·  NIIN 011870695  ·  FSC 5925
NO DASHES 5925011870695
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

41 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AAQLBODY STYLE
ADAQBODY LENGTHINCHES NOMINAL 6.500
ADATBODY WIDTHINCHES NOMINAL 4.125
ADAUBODY HEIGHTINCHES NOMINAL 3.875
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 3.938
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 1.344
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 3.312
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 3.688
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHTINCHES NOMINAL 0.188
AKPXPOLE QUANTITY3
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED STUD(S) 6
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CBBLFEATURES PROVIDEDADJUSTABLE TRIP RELEASE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 25.0 AND AMPERES DC 25.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 500.0 AND DC 250.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 15000.0 AND DC 10000.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS THERMAL-MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS INSTANTANEOUS AND TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT135.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITYALARM 2
CPSFADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPSALL LOCATIONS AC 125.0 TO 175.0 AND DC 300.0 TO 350.0
CQJXNOMINAL THREAD SIZEINCHES 0.190
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE AND INTERNAL AT POLE THREE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS NOMINAL AT 250 PCT 3600.000
CRCFTRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 50.0
CRTKSWITCH TERMINAL TYPEWIRE LEAD
CSSXSWITCH CURRENT RATING AND TYPE IN AMPSAC 15.0 AND DC 0.25
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 460.0 AND DC 250.0
FREQFREQUENCY IN HERTZ60.0
MATTMATERIALCASE PLASTIC
THSDTHREAD SERIES DESIGNATORUNF
TTQYTERMINAL TYPE AND QUANTITYTHREADED STUD 6

Supersedes

This item replaces cancelled NIINs 015608588 · 010934218. An older drawing citing one of those numbers resolves here.