Home / MS parts / NSN 5925-00-251-3283
NSN 5925-00-251-3283  ·  NIIN 002513283  ·  FSC 5925
NO DASHES 5925002513283
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

34 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CRCFTRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
CTJSUNPACKAGED UNIT WEIGHTOUNCES NOMINAL 2.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHUMIDITY RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT
ABXDBUSHING LENGTHINCHES NOMINAL 0.375
ADAQBODY LENGTHINCHES NOMINAL 1.375
ADATBODY WIDTHINCHES NOMINAL 0.687
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 1000.0 AND DC 1000.0
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
CQJXNOMINAL THREAD SIZEINCHES 0.375
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 2.035
AKPXPOLE QUANTITY1
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
AAQLBODY STYLE
APNQARC QUENCHING METHODAIR
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH24
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 30.0 AND AMPERES DC 30.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 250.0 AND DC 50.0
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 6.000 AND MAXIMUM AT 200 PCT 20.000
CPRJTRIP RELEASE METHODSINGLE LOCATION THERMAL
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT135.0
CPRQRESET METHODMANUAL
FREQFREQUENCY IN HERTZ400.0
MATTMATERIALCASE PLASTIC
THSDTHREAD SERIES DESIGNATORUNF
TTQYTERMINAL TYPE AND QUANTITYSCREW 2
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.020
AFJNFRAGILITY FACTORMODERATELY RUGGED