NSN 5930-01-017-6570 · NIIN 010176570 · FSC 5930
NO DASHES 5930010176570
In Stock
SWITCH,THERMOSTATIC
Switches
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 4.750 |
| ABPM | BODY DIAMETER | INCHES NOMINAL 0.625 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 3.437 |
| AKBY | TEMP SENSING ELEMENT TYPE | EXPANDING SHELL |
| ASDB | WIDTH ACROSS FLATS | INCHES NOMINAL 1.000 |
| AWTN | OPERATING TEMP RATING | FAHRENHEIT MINIMUM -0.0 AND FAHRENHEIT MAXIMUM 700.0 |
| AXGY | MOUNTING METHOD | THREADED BUSHING |
| CMLP | THREAD QUANTITY PER INCH | 14 |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQJX | NOMINAL THREAD SIZE | SINGLE THREADED BUSHING INCHES 0.500 |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION 1 |
| CSCF | TERMINAL TYPE | WIRE LEAD |
| CTHF | CONTACT LOAD CURRENT RATING | FIRST VOLTAGE AMPERES RESISTIVE LOAD 5.0 |
| CTHF | CONTACT LOAD CURRENT RATING | SECOND VOLTAGE AMPERES RESISTIVE LOAD 10.0 |
| CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CTYM | CONTACT ADJUSTMENT RANGE | ACTUATION POINT DEGREES FAHRENHEIT -100.00 TO 600.00 AND DEACTUATION POINT DEGREES FAHRENHEIT -100.00 TO 600.00 |
| CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | FIRST VOLTAGE AC AT SEA LEVEL 230.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | SECOND VOLTAGE AC AT SEA LEVEL 115.0 |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| STYL | STYLE DESIGNATOR | |
| THSD | THREAD SERIES DESIGNATOR | SINGLE THREADED BUSHING NPT |