NSN 5930-01-093-6009 · NIIN 010936009 · FSC 5930
NO DASHES 5930010936009
In Stock
SWITCH,FLOW
Switches
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 1.380 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.415 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 1.000 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 0.875 |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.130 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | INCHES NOMINAL 1.125 |
| AWTN | OPERATING TEMP RATING | CELSIUS MAXIMUM 85.0 AND CELSIUS MINIMUM 1.0 |
| AXGY | MOUNTING METHOD | BRACKET(S) AND UNTHREADED HOLE(S) |
| CQGB | CONTACT ACTION STIMULUS | DECREASE |
| CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION 1 |
| CSCF | TERMINAL TYPE | WIRE HOOK |
| CTHF | CONTACT LOAD CURRENT RATING | FIRST VOLTAGE AMPERES RESISTIVE LOAD 2.0 |
| CTHF | CONTACT LOAD CURRENT RATING | SECOND VOLTAGE AMPERES RESISTIVE LOAD 1.0 |
| CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
| CTYX | CONTACT STIMULUS RATING | ACTUATION POINT NOMINAL FEET PER MINUTE 250.00 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | FIRST VOLTAGE AC AT SEA LEVEL 115.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | SECOND VOLTAGE DC AT SEA LEVEL 28.0 |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS |
| STYL | STYLE DESIGNATOR |