| MRC | Requirement | Value |
|---|---|---|
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 4.000 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.937 |
| AWTN | OPERATING TEMP RATING | FAHRENHEIT MINIMUM -20.0 AND FAHRENHEIT MAXIMUM 165.0 |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQJB | PROOF PRESSURE | POUNDS PER SQUARE INCH 400.00 |
| CSCF | TERMINAL TYPE | SCREW |
| CTHF | CONTACT LOAD CURRENT RATING | FIRST VOLTAGE AMPERES INDUCTIVE LOAD 3.0 |
| CTHF | CONTACT LOAD CURRENT RATING | THIRD VOLTAGE AMPERES INDUCTIVE LOAD 10.0 |
| CTHF | CONTACT LOAD CURRENT RATING | SECOND VOLTAGE AMPERES INDUCTIVE LOAD 10.0 |
| CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CTYM | CONTACT ADJUSTMENT RANGE | ACTUATION POINT POUNDS PER SQUARE INCH GAGE 0.60 TO 15.00 AND DEACTUATION POINT POUNDS PER SQUARE INCH 0.50 TO 14.20 |
| CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SERRATED NUT AND EXTERNAL ACTUATION POINT SERRATED NUT |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | FIRST VOLTAGE AC AT SEA LEVEL 480.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | SECOND VOLTAGE AC AT SEA LEVEL 250.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | THIRD VOLTAGE AC AT SEA LEVEL 125.0 |