NSN 5930-01-299-5567 · NIIN 012995567 · FSC 5930
NO DASHES 5930012995567
In Stock
SWITCH,PUSH
Switches
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAJD | THREAD CLASS | 2A |
| AAQL | BODY STYLE | |
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 2.375 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.220 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.031 |
| ABXD | BUSHING LENGTH | INCHES NOMINAL 0.562 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 1.750 |
| ADAT | BODY WIDTH | INCHES NOMINAL 1.031 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 0.469 |
| AFUS | ACTUATOR HEIGHT | INCHES NOMINAL 0.188 |
| AFXE | MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AXGY | MOUNTING METHOD | THREADED BUSHING |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.469 |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | SINGLE SWITCH UNIT POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED 12 |
| CXQR | CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | AMPERES RESISTIVE DC 3.000 AND AMPERES RESISTIVE AC 3.000 |
| PMLC | PRECIOUS MATERIAL AND LOCATION | GOLD CONTACT SURFACES AND SILVER TER-INAL SURFACES AND CONTACTS |
| THSD | THREAD SERIES DESIGNATOR | UNS |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 36 |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 80312C | 14195 |