NSN 5945-00-201-6071 · NIIN 002016071 · FSC 5945
NO DASHES 5945002016071
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.430 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.000 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 1.430 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.562 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 12.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD MILLIAMPERES DC 500.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | DC 25.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 14 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY UNTHREADED HOLE(S) 2 |
| AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 4C |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY IN-LINE |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING MILLIAMPERES DC 70.0 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING OHMS NOMINAL 160.0 |
| APNP | DUTY TYPE | INTERMITTENT |
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.125 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| TS1626 | 77342 |
| TSA1176SANDTSA11765 | 77342 |
| 18050 | 02546 |