NSN 5945-00-257-8951 · NIIN 002578951 · FSC 5945
NO DASHES 5945002578951
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAJD | THREAD CLASS | 2B |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 5.870 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.563 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.120 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.620 |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.125 |
| AJSS | FREQUENCY IN HERTZ | NOMINAL 60.0 |
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING OHMS NOMINAL 102.0 |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY UNTHREADED HOLE(S) 3 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY TRIANGLE |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION 2 |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING MILLIAMPERES AC 105.0 |
| CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | SINGLE MOUNTING FACILITY INCHES NOMINAL 4.000 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS AC 25 DEG CELSIUS 115.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 25.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 250.0 |
| FEAT | SPECIAL FEATURES | TROPICALIZED |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| K41486TYPE131-642M0DIFIED | 63743 |
| K41486TYPE131-642 | 63743 |
| 429-102 | 80063 |