NSN 5945-00-405-4034 · NIIN 004054034 · FSC 5945
NO DASHES 5945004054034
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 1 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY RECTANGULAR |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 3.500 |
| ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
| CQJX | NOMINAL THREAD SIZE | SINGLE MOUNTING FACILITY INCHES 0.164 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 4.593 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 2.625 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 2.125 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 2.0 AND AMPERES DC 2.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 120.0 AND DC 28.0 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC) |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY THREADED HOLE(S) 4 |
| AAJD | THREAD CLASS | 2B |
| APNP | DUTY TYPE | CONTINUOUS |
| AJSS | FREQUENCY IN HERTZ | NOMINAL 60.0 |
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.000 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 5 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS AC 25 DEG CELSIUS 440.0 |