NSN 5945-00-552-4021 · NIIN 005524021 · FSC 5945
NO DASHES 5945005524021
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | DC 6.0 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 2.500 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY IN-LINE |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION 1 |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING AMPERES DC 3.25 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES DC 35.0 |
| CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | SINGLE MOUNTING FACILITY INCHES NOMINAL 2.125 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 3 |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY SLOTTED HOLE 2 |
| ABTD | MOUNTING SLOT WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.375 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 3.500 |
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING OHMS NOMINAL 19.0 |
| FEAT | SPECIAL FEATURES | INSULATED COIL REQUIRES A GROUNDED PUSH SWITCH FOR OPERATION |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.400 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 6.0 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
Supersedes
This item replaces cancelled NIIN 003750476. An older drawing citing one of those numbers resolves here.