NSN 5945-00-556-6605 · NIIN 005566605 · FSC 5945
NO DASHES 5945005566605
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
16 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AKDX | WINDING QUANTITY | 1 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 125.0 |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING MILLIAMPERES DC 80.0 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 12.0 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 2.340 |
| APCN | COIL QUANTITY | 1 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.000 |
| TTQY | TERMINAL TYPE AND QUANTITY | CONTACTS STANDARD TUBE BASE 4 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 7.0 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING OHMS NOMINAL 150.0 |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY PLUG-IN TERMINAL(S) 1 |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION 2 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 2.840 |
| TTQY | TERMINAL TYPE AND QUANTITY | ENERGIZING ELEMENT STANDARD TUBE BASE 2 |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| KL4040 | 77342 |