NSN 5945-00-808-7475 · NIIN 008087475 · FSC 5945
NO DASHES 5945008087475
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| APNP | DUTY TYPE | CONTINUOUS |
| CQJX | NOMINAL THREAD SIZE | SINGLE MOUNTING FACILITY INCHES 0.112 |
| AAJD | THREAD CLASS | 2A |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 28.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES DC 5.0 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.340 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 0.970 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 1.980 |
| AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
| APCN | COIL QUANTITY | 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY THREADED STUD(S) 3 |
| AKDX | WINDING QUANTITY | 1 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 8 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY TRIANGLE |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING MILLIAMPERES DC 100.0 |
| CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | SINGLE MOUNTING FACILITY INCHES NOMINAL 1.000 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | DC 30.0 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC) |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
Cross-references
5 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| C-5589-A | 52401 |
| 25622557 | 80234 |
| 33HSX156 | 94696 |
| 26020024REVB | 99167 |
| 26020024 | 99167 |
Supersedes
This item replaces cancelled NIIN 008549976. An older drawing citing one of those numbers resolves here.