| MRC | Requirement | Value |
|---|---|---|
| ABMK | OVERALL WIDTH | INCHES NOMINAL 3.125 |
| APFR | CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 2 |
| CYCT | CONTACT MAXIMUM CURRENT RATING IN AMPS | AC 16.1 |
| CYCU | HEATER VOLTAGE RATING IN VOLTS | 220.0 |
| CYCW | DELAY TIME IN SECONDS | FIXED OPERATE NOMINAL 60.0 |
| FEAT | SPECIAL FEATURES | TWO 0.203 IN. DIA MTG HOLES ON 4.250 IN. DIAGONAL MTG CENTERS; W/MANUAL RESET BUTTON; 120.0 SEC RELEASE TIME |
| TTQY | TERMINAL TYPE AND QUANTITY | PIN 5 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 3.625 |
| CYCS | CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 220.0 |