NSN 5945-00-827-8686 · NIIN 008278686 · FSC 5945
NO DASHES 5945008278686
In Stock
RELAY,THERMAL
Relays and Solenoids
Technical characteristics
11 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES MINIMUM 1.625 AND INCHES MAXIMUM 1.750 |
| CYCU | HEATER VOLTAGE RATING IN VOLTS | 26.5 |
| TTQY | TERMINAL TYPE AND QUANTITY | PIN 8 |
| CYCT | CONTACT MAXIMUM CURRENT RATING IN AMPS | AC 1.5 |
| APFR | CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | PLUG-IN 1 |
| ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
| CYCS | CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 230.0 |
| ADAV | OVERALL DIAMETER | INCHES MINIMUM 1.271 AND INCHES MAXIMUM 1.301 |
| CYCV | HEATER POWER RATING IN WATTS | 3.0 |
| CYCW | DELAY TIME IN SECONDS | FIXED OPERATE NOMINAL 45.0 |
Cross-references
6 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 26-5-45SB | 22525 |
| 278821 | 1PQF4 |
| 26-5-45B | 22525 |
| 278821 | 36378 |
| 26.5-45-SB | 57741 |
| 68402007301 | 89944 |
Supersedes
This item replaces cancelled NIIN 005813798. An older drawing citing one of those numbers resolves here.