NSN 5945-00-834-4542 · NIIN 008344542 · FSC 5945
NO DASHES 5945008344542
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AKDX | WINDING QUANTITY | 1 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.718 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 1.125 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 1.406 |
| AAJD | THREAD CLASS | 2A |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 1.687 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 14 |
| ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY COIL VOLTAGE 61 V NOM |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 1.0 AND AMPERES DC 1.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 29.0 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC) |
| CQJX | NOMINAL THREAD SIZE | SINGLE MOUNTING FACILITY INCHES 0.138 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY IN-LINE |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 4 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 61.0 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY THREADED STUD(S) 2 |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING KILOHMS NOMINAL 2.0 |
| APNP | DUTY TYPE | CONTINUOUS |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 30896 | 96214 |