NSN 5945-00-905-5749 · NIIN 009055749 · FSC 5945
NO DASHES 5945009055749
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
16 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | DC 28.0 |
| APCN | COIL QUANTITY | 1 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES DC 1.0 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 1.270 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 8 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING OHMS NOMINAL 350.0 |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY UNTHREADED HOLE(S) 2 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 1.062 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 0.400 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 0.790 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.125 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY IN-LINE |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 2 |
| AKDX | WINDING QUANTITY | 1 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 3SAT1039A1 | 1DUQ5 |
| SS408 | 96238 |
| 3SAT1039A1 | 01526 |