NSN 5945-00-914-1399 · NIIN 009141399 · FSC 5945
NO DASHES 5945009141399
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAJD | THREAD CLASS | 2A |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| AKDX | WINDING QUANTITY | 1 |
| CQJX | NOMINAL THREAD SIZE | SINGLE MOUNTING FACILITY INCHES 0.112 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 12.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES DC 3.0 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.270 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 0.820 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.800 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.220 |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 1 |
| CRXH | TIME DELAY | FIXED OPERATE AND RELEASE TIME SECONDS NOMINAL 0.007 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING OHMS NOMINAL 675.0 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY THREADED STUD(S) 2 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | DC 32.0 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 0.790 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY DIAGONAL |
| THSD | THREAD SERIES DESIGNATOR | SINGLE MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 5 |
Cross-references
2 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 22648 | 56623 |
| BR12SH675C6-12V | 56623 |