NSN 5945-01-319-1654 · NIIN 013191654 · FSC 5945
NO DASHES 5945013191654
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Application: AN/SLQ-48,(UC
Technical characteristics
28 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAJD | THREAD CLASS | 2A |
| AAJF | THREAD DIRECTION | SINGLE MOUNTING FACILITY RIGHT-HAND |
| ABHP | OVERALL LENGTH | INCHES MINIMUM 1.210 AND INCHES MAXIMUM 1.250 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES MINIMUM 0.873 AND INCHES MAXIMUM 0.877 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY INCHES MINIMUM 0.623 AND INCHES MAXIMUM 0.627 |
| ABKW | OVERALL HEIGHT | INCHES MINIMUM 1.890 AND INCHES MAXIMUM 1.930 |
| ABMK | OVERALL WIDTH | INCHES MINIMUM 0.960 AND INCHES MAXIMUM 1.000 |
| ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AGAV | END ITEM IDENTIFICATION | AN/SLQ-48,(UC |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY THREADED STUD(S) 4 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBME | CUBIC MEASURE | CUBIC INCHES 1.900 |
| CMLP | THREAD QUANTITY PER INCH | 40 |
| CQJX | NOMINAL THREAD SIZE | SINGLE MOUNTING FACILITY INCHES 0.112 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY RECTANGULAR |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 2 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 28.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 2.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | INDUCTIVE LOAD AMPERES AC 6.0 AND AMPERES DC 1.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS WIRE HOOK 10 |
Cross-references
4 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 5267662-001 | 53711 |
| AE113-040-99 | 55901 |
| D02A3A2 | 15420 |
| 600-249 | 15420 |