Home / MS parts / NSN 5945-00-225-8692
NSN 5945-00-225-8692  ·  NIIN 002258692  ·  FSC 5945
NO DASHES 5945002258692
In Stock

RELAY,ELECTROMAGNETIC

Relays and Solenoids

Technical characteristics

36 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AFJNFRAGILITY FACTORMODERATELY RUGGED
APNAWINDING DC RESISTANCE RATINGSINGLE WINDING OHMS NOMINAL 160.0
APCNCOIL QUANTITY1
APNQARC QUENCHING METHODAIR
AXHRMOUNTING FACILITY TYPE AND QUANTITYFIRST MOUNTING FACILITY UNTHREADED HOLE(S) 4
AXHRMOUNTING FACILITY TYPE AND QUANTITYSECOND MOUNTING FACILITY UNTHREADED HOLE(S) 4
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CBMECUBIC MEASURECUBIC INCHES 10.562
AEBVUNTHREADED MOUNTING HOLE DIAMETERSECOND MOUNTING FACILITY INCHES NOMINAL 0.173
AKDXWINDING QUANTITY1
APNPDUTY TYPECONTINUOUS
ADZCENVIRONMENTAL PROTECTIONHERMETIC
AEBVUNTHREADED MOUNTING HOLE DIAMETERFIRST MOUNTING FACILITY INCHES NOMINAL 0.173
AKSLPURPOSE FOR WHICH DESIGNEDGENERAL
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSECOND MOUNTING FACILITY INCHES NOMINAL 1.000
ABKWOVERALL HEIGHTINCHES MAXIMUM 2.600
ABMKOVERALL WIDTHINCHES MAXIMUM 1.625
ABHPOVERALL LENGTHINCHES MAXIMUM 2.500
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHFIRST MOUNTING FACILITY INCHES NOMINAL 2.125
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSECOND MOUNTING FACILITY INCHES NOMINAL 2.125
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHFIRST MOUNTING FACILITY INCHES NOMINAL 1.000
CSXFOPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS DC 25 DEG CELSIUS 28.0
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEINDUCTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 10.0
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGELAMP LOAD AMPERES AC 2.0 AND AMPERES DC 2.0
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEMOTOR LOAD AMPERES AC 6.0 AND AMPERES DC 6.0
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 10.0
CWABMAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 28.0
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-6106
TTQYTERMINAL TYPE AND QUANTITYALL FUNCTIONS SCREW 8
ZZZKSPECIFICATION/STANDARD DATAGOVERNMENT STANDARD 96906--S24149
CRXHTIME DELAYFIXED OPERATE TIME SECONDS MAXIMUM 0.025
CRXHTIME DELAYFIXED RELEASE TIME SECONDS MAXIMUM 0.01
CQYJMOUNTING FACILITY PATTERNFIRST MOUNTING FACILITY RECTANGULAR
CQYJMOUNTING FACILITY PATTERNSECOND MOUNTING FACILITY RECTANGULAR
CRNGNONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 2
CRPQNOMINAL OPERATING CURRENT RATING AND TYPESINGLE WINDING MILLIAMPERES DC 250.0

Supersedes

This item replaces cancelled NIINs 000080534 · 001983933 · 006366834 · 006657140 · 006553383 · 008458841 · 008511904 · 008406467. An older drawing citing one of those numbers resolves here.