NSN 5950-00-018-5529 · NIIN 000185529 · FSC 5950
NO DASHES 5950000185529
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 380.0 AND HERTZ MAXIMUM 420.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL |
| ADAQ | BODY LENGTH | INCHES NOMINAL 0.750 |
| ADAT | BODY WIDTH | INCHES NOMINAL 0.750 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 1.125 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 0.813 |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED STUD(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CMLP | THREAD QUANTITY PER INCH | 40 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.112 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY AMPERES AC MAXIMUM 1.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 208.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 115.00 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | FERRULE CLIP 8 |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 63504 | 24930 |