NSN 5950-00-027-2792 · NIIN 000272792 · FSC 5950
NO DASHES 5950000272792
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 3.680 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.190 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAT | BODY WIDTH | INCHES MAXIMUM 2.250 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 2.300 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.120 |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SINGLE GROUP FLANGE AND UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY AMPERES AC MINIMUM 1.0 AND AMPERES AC MAXIMUM 2.0 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT SINGLE SECONDARY VOLTS-AMPERES 244.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 55.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 122.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 6 |
Cross-references
2 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 310-0210-001 | 97896 |
| 4556 | 11537 |