NSN 5950-00-044-5577 · NIIN 000445577 · FSC 5950
NO DASHES 5950000445577
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
16 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.000 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.500 |
| ABTD | MOUNTING SLOT WIDTH | SINGLE GROUP INCHES NOMINAL 0.219 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
| ADAQ | BODY LENGTH | INCHES NOMINAL 4.437 |
| ADAT | BODY WIDTH | INCHES NOMINAL 3.500 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 4.875 |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP FLANGE AND SLOT |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 101.00 AND AC VOLTS NOMINAL 103.00 AND AC VOLTS NOMINAL 105.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 116.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | SCREW 12 |