NSN 5950-00-159-1376 · NIIN 001591376 · FSC 5950
NO DASHES 5950001591376
In Stock
TRANSFORMER,POWER
Coils and Transformers
Application: WSD: AIRCRAFT, HAWKEYE E-2C
Technical characteristics
22 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 0.984 AND INCHES MAXIMUM 1.016 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 0.756 AND INCHES MAXIMUM 0.891 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 2.187 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAQ | BODY LENGTH | INCHES MINIMUM 1.813 AND INCHES MAXIMUM 1.938 |
| ADAT | BODY WIDTH | INCHES MINIMUM 1.687 AND INCHES MAXIMUM 1.812 |
| ADAU | BODY HEIGHT | INCHES MINIMUM 2.250 AND INCHES MAXIMUM 2.438 |
| AGAV | END ITEM IDENTIFICATION | WSD: AIRCRAFT, HAWKEYE E-2C |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.138 |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 240.00 |
| FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | PIN 4 |