| MRC | Requirement | Value |
|---|---|---|
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 32.20 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 200.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 26.00 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 4 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT SINGLE PRIMARY VOLTS-AMPERES 39.8 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 26.00 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 2.460 AND INCHES MAXIMUM 2.480 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC NOMINAL 204.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC NOMINAL 384.0 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 5.7 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT FOURTH SECONDARY VOLTS-AMPERES 7.5 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 6.6 |
| TTQY | TERMINAL TYPE AND QUANTITY | TURRET 16 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 2.090 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 1.360 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 3.000 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.490 AND INCHES MAXIMUM 1.510 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.138 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC NOMINAL 73.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC NOMINAL 290.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT THIRD SECONDARY VOLTS-AMPERES 10.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 78.20 |
Cross-references
4 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
Supersedes
This item replaces cancelled NIIN 004361319. An older drawing citing one of those numbers resolves here.