NSN 5950-00-211-2658 · NIIN 002112658 · FSC 5950
NO DASHES 5950002112658
In Stock
REACTOR-TRANSFORMER
Coils and Transformers
Technical characteristics
28 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY FIRST CENTER GROUP INCHES NOMINAL 4.500 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SECOND CENTER GROUP INCHES NOMINAL 3.000 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY FIRST CENTER GROUP INCHES NOMINAL 3.500 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SECOND CENTER GROUP INCHES NOMINAL 2.500 |
| ABTD | MOUNTING SLOT WIDTH | ALL GROUPINGS INCHES NOMINAL 0.188 |
| ACZB | FREQUENCY RATING | ALL COMPONENTS HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | FIRST COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZX | WINDING SHIELDING METHOD | FIRST COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | ALL GROUPINGS SLOT |
| BKPL | RATING METHOD | FIRST COMPONENT ALL SECONDARY ELECTRICAL |
| BKPL | RATING METHOD | FIRST COMPONENT SINGLE PRIMARY ELECTRICAL |
| BPLC | WINDING FUNCTION AND QUANTITY | FIRST COMPONENT PRIMARY 1 AND SECONDARY 5 |
| CRBZ | WINDING OPERATING CURRENT | FIRST COMPONENT FIRST SECONDARY AMPERES DC NOMINAL 5.0 |
| CRBZ | WINDING OPERATING CURRENT | FIRST COMPONENT FOURTH SECONDARY MILLIAMPERES AC NOMINAL 125.0 |
| CRBZ | WINDING OPERATING CURRENT | FIRST COMPONENT SECOND SECONDARY AMPERES AC NOMINAL 1.5 |
| CRBZ | WINDING OPERATING CURRENT | FIRST COMPONENT THIRD SECONDARY MILLIAMPERES AC NOMINAL 400.0 |
| CRGS | DC RESISTANCE RATING IN OHMS | 0.3 |
| CWJS | WINDING OPERATING VOLTAGE | FIRST COMPONENT FIRST SECONDARY DC VOLTS NOMINAL 45.00 |
| CWJS | WINDING OPERATING VOLTAGE | FIRST COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | FIRST COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 28.00 |
| CWJS | WINDING OPERATING VOLTAGE | FIRST COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | FIRST COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 6.50 |
| FEAT | SPECIAL FEATURES | 1PRIMARY WINDING; 5SECONDARY WINDINGS |
| PRPY | PROPRIETARY CHARACTERISTICS | PACS |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 14 |
Cross-references
4 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 71262018-01 | 1K426 |
| TA1121 | 20284 |
| 40009 | 22558 |
| 71262018-01 | 99932 |