NSN 5950-00-243-5805 · NIIN 002435805 · FSC 5950
NO DASHES 5950002435805
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
18 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 13.500 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 5.000 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 6.750 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 6.875 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 8.375 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.375 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 55.0 AND HERTZ MAXIMUM 65.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAQ | BODY LENGTH | INCHES NOMINAL 10.000 |
| AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELL |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC MAXIMUM 400.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 105.00 AND AC VOLTS NOMINAL 110.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 120.00 AND AC VOLTS NOMINAL 125.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 2.26 |
| TTQY | TERMINAL TYPE AND QUANTITY | SOLDER STUD 9 |