NSN 5950-00-295-7500 · NIIN 002957500 · FSC 5950
NO DASHES 5950002957500
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AXGY | MOUNTING METHOD | SINGLE GROUP FLANGE AND UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 3 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 25.0 |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AKNA | INCLOSURE TYPE | OPEN |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.375 |
| ADAT | BODY WIDTH | INCHES NOMINAL 1.906 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 2.438 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 50.0 OR HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAQ | BODY LENGTH | INCHES NOMINAL 1.969 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 150.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 6.30 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 750.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 200.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 9 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 15.00 |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 902T | 30646 |