NSN 5950-00-426-5782 · NIIN 004265782 · FSC 5950
NO DASHES 5950004265782
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ADAQ | BODY LENGTH | INCHES NOMINAL 1.916 |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES MINIMUM 0.280 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO SINGLE PHASE |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.812 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.750 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 1.460 |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| TTQY | TERMINAL TYPE AND QUANTITY | SOLDER STUD 16 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| ADAT | BODY WIDTH | INCHES NOMINAL 1.804 |
| AXGY | MOUNTING METHOD | SINGLE GROUP FLANGE AND UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 6 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT ALL SECONDARY AC VOLTS NOMINAL 6.30 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 200.00 |
Cross-references
12 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.