NSN 5950-00-487-7920 · NIIN 004877920 · FSC 5950
NO DASHES 5950004877920
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
22 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.138 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT ALL SECONDARY MILLIAMPERES AC MAXIMUM 8.5 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT ALL SECONDARY AC VOLTS NOMINAL 103.00 AND AC VOLTS NOMINAL 312.00 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.562 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.469 |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 2.219 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 2.156 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 2.938 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 105.0 |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 3 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 10.00 AND AC VOLTS NOMINAL 23.00 AND AC VOLTS NOMINAL 35.00 AND AC VOLTS NOMINAL 115.00 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.625 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 14 |