NSN 5950-00-581-9199 · NIIN 005819199 · FSC 5950
NO DASHES 5950005819199
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
31 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 5.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 6.30 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 45.00 AND AC VOLTS NOMINAL 705.00 AND AC KILOVOLTS NOMINAL 1.29 AND AC KILOVOLTS NOMINAL 1.88 |
| ABTD | MOUNTING SLOT WIDTH | SINGLE GROUP INCHES MINIMUM 0.213 AND INCHES MAXIMUM 0.223 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 50.0 AND KILOHERTZ MAXIMUM 1.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 10.0 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 2.890 AND INCHES MAXIMUM 2.922 |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP SLOT |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 6 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES AC NOMINAL 2.8 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC NOMINAL 600.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES AC NOMINAL 2.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 300.0 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 17.6 |
| TEST | TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 56232-631198 |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 19 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 3.094 AND INCHES MAXIMUM 3.141 |
| FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING AND SIX SECONDARY WINDINGS |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 5.000 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 4.031 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 4.500 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 170.0 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT FOURTH SECONDARY VOLTS-AMPERES 3.78 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT THIRD SECONDARY VOLTS-AMPERES 565.5 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 56.30 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |