NSN 5950-00-647-7784 · NIIN 006477784 · FSC 5950
NO DASHES 5950006477784
In Stock
REACTOR
Coils and Transformers
Technical characteristics
22 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ADAQ | BODY LENGTH | INCHES NOMINAL 2.375 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.125 |
| ACYF | INDUCTANCE TYPE | FIXED |
| ACYV | INDUCTANCE RATING | SINGLE COMPONENT FIRST WINDING MILLIHENRIES MAXIMUM 7.00 |
| ACYV | INDUCTANCE RATING | SINGLE COMPONENT SECOND WINDING MILLIHENRIES MAXIMUM 49.00 |
| ACYV | INDUCTANCE RATING | SINGLE COMPONENT THIRD WINDING MILLIHENRIES MAXIMUM 107.00 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST WINDING MILLIAMPERES DC MAXIMUM 210.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 6 |
| AKDX | WINDING QUANTITY | 3 |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SINGLE GROUP FLANGE AND UNTHREADED HOLE(S) |
| BKPL | RATING METHOD | SINGLE COMPONENT ALL WINDING ELECTRICAL |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND WINDING MILLIAMPERES DC MAXIMUM 53.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD WINDING MILLIAMPERES DC MAXIMUM 28.0 |
| CRGS | DC RESISTANCE RATING IN OHMS | 1.500 |
| CRGS | DC RESISTANCE RATING IN OHMS | 19.000 |
| CRGS | DC RESISTANCE RATING IN OHMS | 35.000 |
| ADAT | BODY WIDTH | INCHES NOMINAL 1.125 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 1.562 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.156 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| M7474171REV0 | 24446 |
| 301437 | 80064 |
| D13729 | 12436 |