NSN 5950-00-648-0404 · NIIN 006480404 · FSC 5950
NO DASHES 5950006480404
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
16 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.625 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.375 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 12.00 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.125 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 3.875 |
| TTQY | TERMINAL TYPE AND QUANTITY | THREADED STUD 8 AND TAB, SOLDER LUG 7 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 145.00 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 60.0 |
| ADAT | BODY WIDTH | INCHES NOMINAL 3.875 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 3.500 |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP FLANGE AND UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 2 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 5.80 |
Cross-references
4 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
Supersedes
This item replaces cancelled NIIN 005684836. An older drawing citing one of those numbers resolves here.