NSN 5950-00-648-6285 · NIIN 006486285 · FSC 5950
NO DASHES 5950006486285
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
15 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ADAQ | BODY LENGTH | INCHES NOMINAL 4.375 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.250 |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 5 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAT | BODY WIDTH | INCHES NOMINAL 3.750 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 5.000 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.500 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 350.0 AND HERTZ MAXIMUM 450.0 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED STUD(S) |
| FEAT | SPECIAL FEATURES | CASE METAL MATERIAL,0.812 IN. O/A H OF TERMINALS,SHIELD W/ONE STANDOFF SOLDER TERMINAL,PRIMARY WINDING 117 V RATING,SECONDARY WINDING RATED 5 V AT 2 AMP,6.3 V AT 600 MA,6.3 V AT 4.5 AMP,6.3 V AT 4.5 AMP,608 V AT 157 MA W/CENTER TAP |
| TTQY | TERMINAL TYPE AND QUANTITY | STANDOFF, SOLDER LUG 13 |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 20571 | 73386 |