NSN 5950-00-681-7098 · NIIN 006817098 · FSC 5950
NO DASHES 5950006817098
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
28 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.062 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 250.0 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 50.0 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.500 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 2.844 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 3.375 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 13 |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED STUD(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 2 AND SECONDARY 4 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST PRIMARY AC VOLTS NOMINAL 125.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 560.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 6.30 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 2.500 |
| AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELL |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 1.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND PRIMARY AC VOLTS NOMINAL 250.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 6.30 |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.138 |
| ADAT | BODY WIDTH | INCHES NOMINAL 3.000 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 6.70 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 600.0 |