TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
16 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 4.1 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 9 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 2.0 |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 3 |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 200.00 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 6.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 5.70 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 117.00 |
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.188 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 60.0 |
| AXGY | MOUNTING METHOD | SINGLE GROUP FLANGE AND UNTHREADED HOLE(S) |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.125 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY AMPERES AC MAXIMUM 1.9 |
Cross-references
2 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 9905 | 81160 |
| 2016813-0701 | 06845 |