NSN 5950-00-869-4812 · NIIN 008694812 · FSC 5950
NO DASHES 5950008694812
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
27 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ADAT | BODY WIDTH | INCHES NOMINAL 3.230 |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE AND THREE PHASE TO SINGLE PHASE |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY AMPERES AC MAXIMUM 2.0 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 4.100 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 33.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 6.60 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 6.60 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.500 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.250 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 280.0 |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 13 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.164 |
| FEAT | SPECIAL FEATURES | 1 PRIMARY; 13 SECONDARY WINDINGS |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 50 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 4.5 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 120.00 OR AC VOLTS NOMINAL 208.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 99.00 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 450.0 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 2.900 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 122.0 |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 21026 | 00638 |