NSN 5950-01-005-4757 · NIIN 010054757 · FSC 5950
NO DASHES 5950010054757
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
16 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES MINIMUM 0.420 AND INCHES MAXIMUM 0.427 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 10.810 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 3.310 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 5.690 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.520 AND INCHES NOMINAL 8.540 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY AMPERES AC MAXIMUM 12.0 |
| CRMJ | WINDING POWER RATING | SINGLE COMPONENT SINGLE SECONDARY KILOVOLT-AMPERES 4.3 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 218.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 208.00 |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 6 |
Cross-references
4 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 136C478H01 | 21856 |
| 136C478H01 | 48306 |
| 44192 | 73386 |
| 136C478H01 | 97942 |